A furnace that will not start is rarely a dead furnace. Most of the time something upstream has stopped it on purpose: a thermostat that is not calling, a switch someone flipped, a filter so clogged the furnace protects itself by shutting down. This guide works the causes in the order they turn up on real service calls, cheapest and most likely first.

To check thermostat, power, door switch and filter
5 min
US average furnace repair, 2026
$318
Typical life of a hot-surface ignitor
3–7 yrs
Ignitor replacement, installed, US range
$150–$500

Repair prices: HomeAdvisor national cost data, June 2026.

Before you touch anything: read the error code

A red diagnostic LED glowing in the sight glass of a furnace door, next to the printed flash-code label
The status LED and its flash-code legend. Your codes are the ones printed on your furnace, not a chart online.

Almost every furnace built in the last 30 years has a control board with a small LED, visible through a sight glass in the lower door. When the furnace locks itself out, that LED blinks a count: two flashes, three flashes, a steady glow. A legend on the inside of the door translates each count into a fault.

Read it before you reset anything. Switching the furnace off and on clears the code, and with it the best clue you had. Technicians read it first, ahead of any of the checks below, and so should you. The code will not name the broken part, but it tells you which part of the sequence failed, and that is usually enough to skip straight to one or two of the causes here.

Then note what the furnace does when you raise the thermostat. That detail alone narrows the list:

What you see, and where to look first
Nothing at all: no click, no fan, no light on the board Causes 1, 2
Inducer grinds or struggles, then the sequence stops Cause 5
Inducer runs smoothly, but the ignitor never glows Causes 6, 5
Ignitor glows, but the burners never light Causes 7, 9
Burners light, then go out after 3 to 7 seconds Cause 4
Burners run, but no air comes out, or it shuts off hot Causes 3, 8, 10

1. Is the thermostat actually calling for heat?

Cause 01 COMMON DIY-friendly

More no-heat calls end at the thermostat than at the furnace. Check four things in this order:

  • Mode and setpoint. The mode must read HEAT, not AUTO-changeover, not COOL, and the setpoint must be at least 3°F above the current room temperature.
  • Batteries. A battery thermostat with a lit screen can still be too weak to close the relay. If the display is dim or the batteries are more than a year old, replace them first.
  • Power to a smart thermostat. Models that draw power from the furnace drop offline when the furnace loses power, which makes a power problem look like a thermostat problem.
  • A schedule or hold. Programmable thermostats routinely get left in an eco or away hold after a vacation.

To rule the thermostat out entirely, pull it off the wall plate and touch the R and W wires together for two seconds. If the furnace starts, the thermostat is the fault. If nothing happens, move on.

2. Has the furnace lost power?

Cause 02 COMMON DIY-friendly

A furnace has several things that can cut its power, and homeowners usually check only one.

The breaker. A tripped breaker can sit in a middle position that reads as “on” at a glance. Push it fully to OFF, then back to ON.

The service switch. A switch that looks exactly like a light switch sits on or beside the furnace, often at the top of the basement stairs. Painters, movers and anyone hunting for a light flip it constantly.

The blower door switch. A plunger switch kills all power while the lower door is off. If the door went back on crooked after a filter change, the furnace is dead by design. Press it firmly and re-latch it. The same switch shuts down your air conditioning in summer, one of the checks in our AC not cooling guide.

The condensate safety switch. High-efficiency furnaces drain water through a trap and often a small pump. When that line clogs, a float switch shuts the furnace down. A full pan under the unit is the tell.

A furnace control board with relays, red and black wires, and a purple 3 amp blade fuse
A 3 amp blade fuse on a control board. A blown one shows a dark, scorched body and a broken metal strip.

The fuse on the control board. Many boards carry a small plug-in fuse, often 3 or 5 amps, that protects the low-voltage circuit. If the board shows no light at all, look at it with the power off: a blown fuse has a broken strip inside and often a scorched, darkened body. Replacing it with one of the same rating is a cheap fix, but a fuse that blows again points to a shorted wire, often the thermostat cable, and that needs a technician.

If the breaker trips again the moment you reset it, stop there. That is a short, and it is not a DIY job.

3. Is the air filter choking the furnace?

Cause 03 COMMON DIY-friendly

This one surprises people, and technicians see it constantly. A filter packed with dust starves the furnace of air. Without enough air moving across the heat exchanger, the furnace overheats, and a limit switch on the burner side cuts the burners to protect it. Some furnaces then lock out entirely.

Slide the filter out and look through it at a bright window. If it is opaque, replace it, then reset the furnace at the service switch: off for 15 seconds or so, then back on. Plenty of “dead” furnaces come back right there.

4. Is the flame sensor dirty?

Cause 04 COMMON DIY-friendly
Hands cleaning a thin metal furnace flame sensor rod with a maroon abrasive pad
Cleaning a flame sensor rod with a fine abrasive pad. One screw holds it in.

If your furnace lights, burns for three to seven seconds, then shuts the gas off, that is the flame sensor almost every time.

The sensor is a thin metal rod sitting in the burner flame. It does not sense heat: it passes a tiny current through the flame itself, on the order of 2 to 6 microamps. When a film of silica and carbon builds up on the rod, that current drops below the board’s threshold, the board concludes there is no flame, and it closes the gas valve. That shutdown is the safety system working correctly.

The fix is genuinely simple: power off at the service switch, remove the sensor’s single mounting screw, slide the rod out, and scuff the metal with a fine abrasive pad or fine steel wool. Do not use sandpaper coarser than about 400 grit: it scores the rod and speeds up the next fouling. Reinstall, restore power, and the furnace should hold flame.

If cleaning buys you two weeks and the fault returns, replace the sensor. If a new sensor still drops out, the problem is grounding or the board.

5. Is the inducer motor or the vent stopping the start?

Cause 05 OCCASIONAL Call a pro
A hand pointing at the black draft inducer motor housing inside a gas furnace
The draft inducer: the first thing that runs on a call for heat, and the source of the startup whine.

The draft inducer is the small blower that starts first, pulling combustion air through the furnace and pushing exhaust out of the vent. A pressure switch has to confirm that airflow before the board will let the ignitor heat up. No proof, no ignition.

Two things break that chain:

  • A failing inducer. A healthy one starts with a smooth, rising whine. Grinding, rattling or a motor that struggles to spin up means bearings on their way out, and a slow inducer never pulls enough draft to close the pressure switch.
  • A blocked vent. On a high-efficiency furnace, walk outside and find the two white PVC pipes where they leave the house. Wasp and mud-dauber nests, leaves, ice and snowdrifts can all block them. Clearing the opening is sometimes the whole repair.

If the inducer runs normally, the vent is clear and the code still points to the pressure switch, the switch, its rubber hose or the condensate trap needs a technician.

6. Is the ignitor dead?

Cause 06 COMMON Call a pro

Every furnace built since the mid-1980s lights with either a hot-surface ignitor or an intermittent spark. The hot-surface type is the single most common failed part in residential heating, and it wears out on a fairly predictable schedule: roughly 3 to 7 years, sooner in a furnace that short-cycles. Spark ignitors fail far less often.

The symptom is specific. The inducer spins up, and roughly 20 to 30 seconds later the ignitor should glow bright orange through the burner opening. Then the gas valve opens and the burners catch from the heat alone. If you hear the inducer but never see that glow, the ignitor is the prime suspect.

A hot-surface ignitor glowing bright orange inside a furnace burner assembly Working
A working ignitor glows bright orange before the gas valve opens.
A hand holding a removed hot-surface ignitor with its white ceramic base and two wires Fragile
Handle an ignitor by its ceramic base only. The element cracks easily, and skin oil shortens its life.

Ignitors are cheap parts, roughly $25 to $60, but the silicon carbide type is brittle enough to crack if you brush it, and the mounting bracket and wiring vary by model. Universal replacement kits exist, and some homeowners fit them, but the ignitor has to sit at exactly the right spot against the burner to light it reliably. This is where the DIY line usually falls: budget $150 to $300 installed and let a technician match the part.

7. Is gas actually reaching the furnace?

Cause 07 OCCASIONAL DIY-friendly

The manual shutoff valve on the gas line into the furnace should have its handle parallel to the pipe. Perpendicular means closed. Valves get closed during appliance work, water heater replacements and remodels, then forgotten.

Then check another gas appliance. If your range will not light either, the problem is upstream of the furnace: a utility outage, an account issue, or a tripped excess-flow valve at the meter. Call the utility, not a contractor.

On propane, a tank gauge under about 15% may not deliver enough pressure even though it is not on zero.

8. Is the blower motor or its capacitor gone?

Cause 08 OCCASIONAL Call a pro

If the burners light but no air ever moves, or you hear a hum from the blower compartment without rotation, suspect the run capacitor first and the motor second. A weak capacitor cannot get the motor turning; the motor heats up, the furnace hits its high limit and shuts the burners off.

There is one safe check you can do yourself. With the power off at the switch and the blower door removed, reach in and spin the blower wheel by hand. It should turn freely and coast. If it is stiff, gritty or will not turn, the motor bearings are seized and the motor needs replacing.

A hand spinning the squirrel-cage blower wheel inside a furnace with the power off Spin test
Power off, door off: the wheel should spin freely and coast to a stop.
A multimeter in capacitance mode connected to a 20 microfarad run capacitor, reading 20.00 Meter test
This 20 µF capacitor reads 20.00 µF, inside its 19 to 21 µF tolerance. Below 19, it is failing.

The capacitor is a metal can, usually oval, near the blower. You can spot a dead one by eye: a domed or bulging top, terminals pushed out of line, or oily residue. Testing it means discharging it and reading it with a meter that measures microfarads. A capacitor is rated with a tolerance, typically ±5%, so a 20 µF part should read between 19 and 21; anything below that is failing, and a reading near zero means it is dead. It stores a dangerous charge even with the power off, so unless you own the meter and know how to discharge one, leave this to a technician. Capacitors run $150 to $250 installed; a blower motor runs $450 to $900 depending on whether it is a standard PSC or a variable-speed ECM motor.

9. Has the control board failed?

Cause 09 RARE Call a pro

The control board runs the whole sequence: inducer, pressure switch proof, ignitor warm-up, gas valve, flame proof, blower. When it fails, the furnace can be completely dead, stuck at one step, or intermittent in ways that make no sense, fine in the evening and dead at 6 a.m.

This is where the code you wrote down earns its keep. Three flashes means an open pressure switch on one brand and a limit fault on another, and that code is the difference between a $30 part and a $600 one. Boards run $400 to $700 installed. Before you approve that on a furnace over 15 years old, get a replacement quote for comparison.

The comparison worth making is efficiency, not just price. ENERGY STAR notes that its certified gas furnaces run up to 16% more efficient than standard models in the South and up to 18% in the North, which decides whether a $600 repair on an old unit is thrift or money thrown away.

How Long Does a Furnace Last? Repair or Replace an Old One (2026) Facing a big repair on an older unit? Run the safety and 50% tests before you approve it.

10. Is the AC coil above the furnace clogged?

Cause 10 RARE Call a pro
Close-up of the aluminum fins of an A-shaped evaporator coil that sits above a furnace
The evaporator coil sits on top of the furnace. Years of dust that slipped past the filter collect on its fins.

If you have central air, the evaporator coil sits directly on top of the furnace, usually shaped like an A. Every bit of air the furnace heats has to pass through it. Years of running with a dirty or missing filter can mat its fins with dust, and the result looks exactly like a clogged filter: too little airflow, an overheating furnace, a limit switch that keeps shutting the burners off.

It is far less common than a dirty filter, because it takes a lot of debris, but it is the next suspect when a new filter does not fix an overheating furnace. Cleaning a coil means opening the plenum above the furnace and is a technician’s job.

What a normal startup should sound like

Knowing the healthy sequence tells you where yours is stopping:

  1. Thermostat calls. A relay clicks.
  2. The draft inducer spins up, a rising whine lasting 20 to 60 seconds.
  3. The pressure switch closes with an audible snap.
  4. The ignitor warms and glows orange for 15 to 45 seconds.
  5. The gas valve clicks open and the burners light with a soft whoosh.
  6. The flame is proved within about 5 seconds.
  7. The blower starts 30 to 60 seconds later, once the heat exchanger is warm.

Tell a technician which step yours reaches, and the code you wrote down, and you have handed them half the diagnosis before they open the panel.

Most of these faults announce themselves months ahead to someone who is looking. The US Fire Administration advises having heating equipment and chimneys cleaned and inspected each year by a professional, and keeping anything that burns at least three feet clear of the unit.